Memory Error Stimulation 2 Register
MEEEC | Memory Error: Error Enable Counter. Error stimulation is activated if the MENEC = 0x0 and the MEEEC bit field value > 0. This bit field is automatically decremented after each event of an error stimulation (defined by the CANFD_MEM_ES_3[MEL] bit field and the CANFD_MEM_ES_3[MES] bit) until it reaches the value 0x0. |
MENEC | Memory Error: No Error Counter. Error stimulation is delayed if the MEEEC bit field value > 0. The MEEEC bit field value is automatically decremented after each memory read access (defined by the CANFD_MEM_ES_3[MEL] bit field and the CANFD_MEM_ES_3[MES] bit) until it reaches the value 0x0. |